Opticon LGZ 7225 Scanner User Manual


 
Codabar
Insertion group selection: Refer to Insertion group
selection of UPCA.
Start/End type: The Codabar has four pairs of Start/End
pattern; you may select one pair to match your application.
Start/End Transmission: Refer to Start/End Transmission of
Code 39.
Program
Option Bar Code Option Alphanumeric
Entry
Insert group
selection
00-44 00-44
00
Start/End type
ABCD/ABCD
abcd/abcd
ABCD/TN*E
Abcd/tn*e
00
01
02
03
Start/End
transmission
Disable
Enable
00
01
Exit
53