Opticon RS232 Scanner User Manual


 
Manual No. 25-ULGPMU01-01 Series LGP Handheld CCD Scanner
Codabar Settings (continued)
ABC-Code - The ABC code is an acronym for American Blood Commission. The code consists of two bar codes which are
decoded in one read cycle. the code is concatenated when the stop character of the first bar code and the start character of the
second bar code is a D. These two D's are not transmitted.
String format:
start
char.
data (1+
chars.)
check
digit
data (1+
chars.)
check
digit
stop
char.
CX-Code - The CX-Code consists of two are codes which are decoded in one read cycle. The code is concatenated when the stop
character of the first bar code is a C, and the start character of the second bar code is a B. The B and C characters are not
transmitted.
String format:
start
char.
data (1+
chars.)
check
digit
data (1+
chars.)
check
digit
stop
char.
Options for Codabar:
* Enable ABC code concatenation.
* Enable CD code concatenation.
* Enable check digit check.
* Disable transmission of the check digit.
* Disable transmission of start/stop.
* Selection of start/stop character translation.
* Selection of minimum number of data characters.
* Enable library space (CLSI) insertion.
*
Space insertion - This option inserts spaces in position 2, 7 and 13 of the data string for use in library systems.
ST/SP translation - This option enables the translation and transmission of the start and stop characters. Thus, if the option
ST/SP: abcd/tn*e is chosen, the start character is converted to lower case, e.g. from A, B, C or D to a, b, c or d, respectively), and
the stop character is converted from A, B, C or D to t, n, * or e, respectively.
Minimum data characters - Codabar labels are checked for a minimum of 1, 3 or 5 characters as set by the user. If the number of
characters in the label is shorter than the minimum selected, the label will be rejected. If the fixed length option is used for
Codabar type labels, then such labels will additionally be checked for fixed length. This option will no longer be supported in
future software releases.
Intercharacter gap check - This option enables the reading of Codabar labels with a large or irregular gap between characters.