Panamax MAX 5410 Power Supply User Manual


 
7
FEATURE DETAILS
Filtered Outlet Banks
Eight Outlets (4 banks / 2 outlets per bank) are fed through cascaded noise filtration circuits. These circuits are designed to
eliminate AC contamination that is detrimental to the performance of audio or video components like stereo receivers, VCRs
or televisions. The dedicated filters are carefully engineered to provide power filtration and inter-component "noise isolation"
for both “common-mode” (line/neutral to ground) and "normal-mode" (line-to-neutral) EMI/RFI. This means that high-fre-
quency interference will be drastically reduced not only from the incoming power but also from equipment plugged into the
other outlet banks, regardless of what "mode" it occurs in. Even equipment with ungrounded, 2-blade plugs, receives clean
power.
As shown in the diagram, there are four banks of filtered outlets (not counting the High Current outlets and the front panel
convenience outlet). Cascaded filter circuits are used to feed the various banks and provide maximum noise isolation and
attenuation. All 4 banks benefit from the inductorless input filter, the Common Mode Balanced L filter and Normal Mode
Balanced L filter circuits. Outlet banks 2 and 4 receive their clean power through this comprehensive network of filters while
banks 1 and 3 benefit from additional Balanced L filters.
Outlet Banks 1 and 2 contains four switched outlets that will turn your connected equipment ON or OFF with one of two
MAX
® 5410 triggers front panel push-button or Voltage Sense Trigger. A 2-position slide switch located on the rear panel
controls the timing. Together, these outlets can be set as Always-On or with a turn-off delay of 10 seconds to prevent speak-
er "thump". This switch provides the option of having a total of eight always-on outlets. See the Sequential Startup/Shutdown
section for more information.
Outlet Bank 3 and 4 remain ON continually to provide a constant power source for programmable audio/video compo-
nents. A personal video recorder (such as TiVo™) and VCR are two examples of components that require a constant supply
of power. A TiVo™ video recorder relies on continual power to monitor the cable signal and retain its programmed informa-
tion. A VCR should be connected to one of these always-on, filtered outlets to maintain correct clock time and programmed
recording information.
When set to 10 second delay position, these outlets will remain as Switched outlets, controlled by the front panel push-but-
ton and/or the DC Voltage Sense Trigger. In this situation, these outlets will not power down until after the selected time has
elapsed.
USA & Canada (800) 472-5555 • (707) 283-5900 • Fax (707) 283-5901
ER
T
HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS
RS232 CO
12V TR
IN
ER
T
HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS
RS232 C
12V TR
IN
HIGH
CURRENT
OUTLETS
COMMON MODE
DOUBLE "L" FILTER
BANK 1
BANK 2 BANK 3
BANK 4
FILTERED OUTLET BANKS
SWITCHED
OUTLETS
ALWAYS ON
OUTLETS
INDUCTORLESS
INPUT FILTER
POWER PROTECTION
CIRCUITRY
NORMAL
MODE
BALANCED
"L" FILTER
NORMAL
MODE
BALANCED
"L" FILTER
NORMAL
MODE
BALANCED
"L" FILTER
NORMAL
MODE
BALANCED
"L" FILTER
FRONT
PANEL
CONVENIENCE
OUTLET
WALL
OUTLET
1
2
ER
T
HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS
RS232 C
12V TR
IN
3 4