Panasonic A4 Series Power Supply User Manual


 
238
How to Operate from the Front Panel
(1) Turn to the normal auto-gain tuning 
mode from the monitor mode, by 
pressing the SET button, then press
the mode switching button three times.
For details, refer to P.60 and 61, 
"Structure of Each Mode" of Preparation.
(2) Enter the machine stiffness No. by pressing .
Display of rotational speed 
of the motor (initial display)
Machine stiffness No.
Machine stiffness No. (High)
Machine stiffness No. (Low)
Tuning finishes 
normally
Tuning error
Value changes toward the direction as 
an arrow shows by pressing and
changes toward the reversed direction 
by pressing .
(3) Shift to MONITOR/EXECUTION mode 
by pressing .
(4) Operation at MONITOR/EXECUTION mode
Keep pressing until the display 
changes to .
• Pin-29 of the connector, CN X5 to be 
Servo-ON status.
Keep pressing for approx.3sec, 
then bar increase as the right fig. shows. 
The motor starts rotating.
For approx. 15 sec, the motor repeats 
max. 5 cycles of CCW/CW rotation, 
2 revolutions each direction per one cycle. 
Tuning may finish before 5th cycles, 
however, this is not an error.
(5) Write the gain value to EEPROM to prevent 
them from being lost due to the power shut off.
Drive method
Ball screw direct connection
Ball screw + timing belt
Timing belt
Gear, Rack & Pinion
Others, low stiffness machine
Machine stiffness No.
8 –14
6 –12
4 –10
2 – 8
0 – 8
<Caution>
Do not use the normal mode auto-gain tuning with the motor and driver alone. Pr20 (Inertia ratio) be-
comes to 0.
<Notes>
Content
Display of error.
Value of parameter
related to gain (such as
Pr10) is kept as same
as before the execution.
Motor does not run.
Cause
One of alarm, Servo-OFF or
deviation counter clear has
occurred.
Load inertia cannot be identified.
CL (Pin-30) of CN X5 is entered.
Measure
Avoid an operation near the limit switch or origin proximity switch.
• Turn to Servo-ON.
• Release the deviation counter clear
• Lower Pr10 to 10 and Pr11 to 50, then execute the tuning.
• Adjust the gain manually. (Calculate the load inertia, and then
enter.)
Turn off the CL (Pin-30) of CN X5.
Normal Mode Auto-Gain Tuning