AJ9 (J9)
NOTES
REFERENCE
1. Switch mounting
Mount the switch with the recommended
panel mounting hole dimensions shown
in the dimensions.
Contact us if you are considering using a
panel of other than the recommended
size and shape.
2. Regarding fastening lead wires to
terminals
1) When connecting the tab terminals,
use a .250 Quick-connect and insert the
terminals straight in.
If they are skewed, the terminals will
require excessive insertion force.
In addition, there is some variation in the
insertion force required for different
receptacles from different manufacturers,
so confirm how much force is needed
under actual conditions.
Do not solder wires onto tab terminals.
2) With manual soldering: Complete the
soldering connection work within 3
seconds with the tip of the soldering iron
(60W soldering iron) at a temperature of
420°C or lower, and take care not to
apply any force to the terminal area.
Avoid touching the switch with soldering
iron.
3) The terminals should be connected in
such a way that they are not under
constant stress from the connecting
wires.
4) Terminal material is copper alloy which
may discolor due to finger’s oil or after a
long time. But that discoloration does not
effect actual performance.
3. Resistance to chemicals
To clean the switch unit, use a neutral
detergent diluted with water.
Do not use acidic or alkaline solvents as
they may damage the switch.
Furthermore, be careful not to get any of
the detergent solution inside of the switch
while cleaning it.
4. Environment
Avoid using and storing these switches in
a location where they will be exposed to
corrosive gases, silicon, or high dust
levels, all of which can have an adverse
effect on the contacts.
5. Take care not to drop the product as
it may impair perfomance.
1. Outline of UL1054 test
Overload test AJ9: 20A 250V AC
(Power factor 0.75 to 0.8)
50 operation
Endurance test AJ9: 16A 250V AC
(Power factor 0.75 to 0.8)
6×10
3
operation
After testing, temperature rise of
terminals should be less than 30°C and
no abnormality should be observed in
characteristics.
2. Outline of EN61058-1 test
After switching 5 × 10
3
times on the
above load condition at both 85 °C and
25±10°C, temperature rise of terminals
should be less than 55°C and no
abnormality should be observed in
characteristics.
+5
0
24A
50 to 100ms
J9: 16A
AC: 250V
(Power factor 0.6)
2 sec.
4 sec.