Panasonic GT32M/T Computer Monitor User Manual


 
6 7
Simple connection and maintenance
Great diversity and variety of use
GT11
(Enlarged view)
(Enlarged view)
GT
Communications
Power supply
Allows simultaneous
debugging of GT
and PLC.
Screen data
transmission/
PLC debugging
Rear of GT
*1: UL/cUL is not available to white LED backlight type.
*2: When the panel thickness is 5 mm, the screw head of the mounting
bracket protrudes 4 mm.
*3: Compared with GT10.
*4: To use the internal clock function, buy a commercially available battery (CR2032).
*5: The mounting bracket and connector shape are different. When converting the screen data, the font
size will not be automatically converted.
Conventionally, screens were created for each language. With this new
language switching function, data can be entered in all available languages for
each part. The same screens can be created all at once, and ladder diagram
creation is also easier. The character table (below picture) for switching the
language display can be edited in Excel and imported.
FP0FPFP-X
“TrueType fonts” “Analog-touch design”
You can freely position switches as
small as 8 x 8 dots.
The use of a TrueType font allows GT11 to
display up to 216 characters (24 wide x 9
high), GT01/GT01R to display up to 72
characters (12 wide x 6 high), improving
the efficiency of use of the panel space.
“Alarm list” (GT11) “Write Device function”
This function writes the PLC values
or turns bits on/off according to the
PLC status or the screen No.
Alarm activation, check, and recovery
can be recorded and displayed.
“Graph function”
You can identify the production or
operation status in line or bar graph
form.
“Recipe function”
Settings by product item and other
data (up to 3,600 words) can be
transferred to PLC, simplifying PLC
programming.
“Flow Display function”
A flowing message of up to 64 characters
(two-byte) can be displayed at the bottom
of the screen. (128 messages)
Also supports connection
with a PLC of another company
or a microprocessor board.
Other company’s
PLC
Microprocessor
board
If your operating system is Windows 2000 or XP, the above languages can be
displayed on one screen at a time. With other operating systems, the screen
creation tool “Terminal GTWIN English Version” is required, and the operating
system’s language must be the one you want to display.
• The panel face protection sheet for GT11 is available as an option.
Conventional model
(GT10)
Resolution:
225%
240×96
dots
(Compared with our
conventional
model)*
3
Japanese
Simplified
Chinese
Traditional
Chinese
Korean Turkish
English German French Spanish
Italian
Available languages
Higher visibility
Approx. doubled information capacity
160 dots
64 dots
240 dots
96 dots
Normal (Green)
In operation (Orange)
Emergency (Red)
3-color LED Backlight
White LED Backlight
*Unit does not have a red LED.
Portrait orientation possible
The upgraded 4-inch wide screen provides clearer images with higher visibility.
Compact Programmable Display
3-color/ white
backlight
(green/orange/red)/ white
24 chars.
×9 lines
240×96
dots
Through
function
24V DC
RS232C/
RS422
(RS485)
4 inch
monochrome
Common Features
Free switch
layout
(8×8 dots min.)
30 mm
*2
72 mm
144 mm
Mountable in tight places
4-inch wide screen high-definition LCD
The highly visible three-color backlight shows the equipment status and enhances the equipment style.
The 4-inch wide screen consists of a high-definition LCD, which increases the information capacity.
70%
brighter
(than our
conventional
model)*
3
The bright and easy-to-read LCD indicates messages, graphics, switches, lamps, PLC data, graphs, clocks*4, and
others in any layout you want. In addition, three backlight colors can be selected according to the equipment
status. This allows you to identify the status at a glance.
Compatible with our conventional GT10 model
Exchangeable since the panel cut dimensions are identical, and screen
data exchange is also possible. *
5
Costs can be reduced by using this model instead of a mid-size
display.
*1
The through function improves the convenience in
combination with our FP series PLC.
A wide variety of display functions improve the workability for operators.
The language switching function facilitates
PLC programming and screen switching.
There are two types of communication [RS232C/
RS422 (RS485)]. Connection with PLCs of a
variety of manufacturers is possible.
(Please refer to the compatible PLC list.)
The high environmental resistance is
IP65-rated.
For example, when a sensor detects a person, the display
backlight can be turned by an instruction from a PLC.
The RS422 type can be connected at a maximum distance of 500m.
The backlight can be controlled via PLC.
An original screen can be displayed for
a specified period of time after startup.
The use of high-brightness LEDs eliminated backlight replacement work.
Simultaneous operation of GT data transfer and
PLC debugging will be
available by connecting your
GT to a personal computer
and our FP series PLC.
FP2/FP2SH
Ash gray
Black