Appendix
Technical Information
ENGLISH - 46
J Cable specifications
(When connected to a personal computer)
J Control commands
Command Control contents Remarks
PON Power ON
In standby mode, all commands other than the PON command are
ignored.
The PON command is ignored during lamp ON control.
POF Power OFF
If a PON command is received while the cooling fan is operating after the
lamp has switched off, the lamp is not turned back on again straight away
in order to protect the lamp.
AVL Volume
Parameter
000 - 063 (Adjustment value 0 - 63)
IIS INPUT
Parameter:
VID = VIDEO
RG1 = COMPUTER1
SVD = S-VIDEO
RG2 = COMPUTER2
NWP = WIRELESS (PT-LB51NTU only)
Q$S
Lamp condition
query
Call back
0 = Standby
1 = Lamp ON control active
2 = Lamp ON
3 = Lamp OFF control active
OSH SHUTTER
Turning off the projection temporarily.
Send the command to switch between ON and OFF.
Do not send the command consecutively.
If a command other than “OSH” is sent to the projector when the shutter
function is used, the “ER401” command will be sent from the projector to
the computer and the shutter function will be turned off.
Projector PC (DTE)