Settings
SIGNAL LIST
J SIGNAL LIST and SUB MEMORY
LIST
You can register a input signal as a SIGNAL LIST data,
and several sets of adjusted settings for the signal as
SUB MEMORY LIST data.
J Managing the list and the
registered data
Q Registering a signal to the list
When a new format input signal is applied to the
projector, press the MENU button to register to the
SIGNAL LIST.
Q Displaying the signal list and the status
1. Select SIGNAL LIST in the main menu.
2. Press the ENTER button.
Display the REGISTERED SIGNAL LIST.
3. Select the required signal data.
4. Press the ENTER button.
Displays the REGISTERED SIGNAL STATUS.
Q Renaming a registered data
You can rename the automatically determined registered
signal data.
1. Display the REGISTERED SIGNAL LIST and select the
required signal data.
2. Press the ENTER button.
Displays the REGISTERED SIGNAL STATUS of the
signal.
3. Press the ENTER button.
Displays the character list.
4. Select the required character by pressing F G I H
and press the ENTER button.
Repeat until complete the name.
You can enter the characters up to 16.
5. Select OK and press the ENTER button.
Displays the REGISTERED SIGNAL STATUS with NAME
renamed.
Select CANCEL and press the ENTER button to return to
the REGISTERED SIGNAL STATUS without any change.
Q Deleting a registered data
You can delete a registered data from the REGISTERED
SIGNAL LIST.
1. Display the REGISTERED SIGNAL LIST and select the
required signal data.
2. Press the DEFAULT button.
Displays the REGISTERED SIGNAL STATUS of the signal
for confirmation to delete.
3. Press the ENTER button.
Displays REGISTERED SIGNAL LIST and confirm the
data is deleted.
Press the MENU button to cancel and return to the
REGISTERED SIGNAL LIST without any change.
NOTE:
You can register data up to 96 in total number of the signal
data and any corresponding sub memory data.
The signals supporting the installed input module are input
and their data registered.
The names of the registered data are automatically
determined by the input signals and memory numbers.
If a menu is being displayed, the new signals will be registered
at the instant they are input.
NOTE:
The memories are numbered over 12 pages (A to L: 8 data
items can be registered on each page), and the data is
registered in the unused memory with the lowest number. If all
the memories are used, the data of the old signals is
overwritten in sequence.
When a new input signal is applied while the menu is
displayed, the signal will be registered to the list.
Remote control
See “Navigating through the menu” on page 15.
See “Main menu and Sub-menu” on page 12.
NAME Input signal name
MEMORY NO. Location address of registered data
INPUT Connected input terminal
fH Horizontal frequency
fV Vertical frequency
SYNC.STATE Polarity synchronisation