E
NGLISH-51
Adjustments and settings
AUTO SETUP
This should normally be set to
“AUTO”.
AUTO
“AUTO SETUP” will be carried out
when the input signal is changed to
RGB.
BUTTON
“AUTO SETUP” will function only
when you press the AUTO SETUP
button.
SIGNAL SEARCH
This should normally be set to “ON”.
ON
When the power is turned on and
“AUTO SETUP” is running, the
projector detects which signals are
being input, and uses these signals
for projection.
(If a picture is being projected, the
signal source is not automatically
changed.)
OFF
Use this setting when you do not
want the signal source to be
changed automatically when the
power is turned on and “AUTO
SETUP” is running.
POWER OFF TIMER
If no signal is input to the projector
for the duration of the period you
set, the projector will return to
standby mode. The period can be
set from 15 minutes to 60 minutes in
5 minute intervals. If you don’t use
this feature, set it to “DISABLE”.
DIRECT POWER ON
This sets the projector’s start up
status for when the mains lead is
connected.
OFF
The projector will start from the
same status as when the mains
lead was disconnected. If the mains
lead was disconnected during
projection when the projector was
used the last time, projection will
start after the mains lead is
connected.
ON
The projection will start after the
mains lead is connected.
CONTROL PANEL
To disable the buttons on the
projector, set “CONTROL PANEL”
to “INVALID”. A confirmation screen
will then be displayed. Select “OK”
by using I or H button. To use the
buttons on the projector, set to
“VALID” by using the remote control