Panasonic WV-BM1790 Computer Monitor User Manual


 
6
OUT
VIDEO
IN
OUT
VIDEO
IN
Coaxial
Cable
Coaxial Cable
Cameras
First Video
Monitor
Last Video
Monitor
Video Switcher
Connection with the Camera
Site
Connect the Video output of the camera site equipment to
the VIDEO IN connector at the rear of the monitor using a
coaxial cable.
The maximum coaxial cable length between the camera
and the monitor is shown in the table below.
Cable
CONNECTIONS
The connections described below should be made by qualified service personnel or system installers.
An example of a basic connection is shown below.
A
IN
Video Switcher
AC IN
OUT
VIDEO
IN
CCIR EIA
Cable length
RG-59/U
3C-2V
RG-6/U
5C-2V
RG-11/U
7C-2V
RG-15/U
10C-2V
500 m
(1 650 ft)
750 m
(2 475 ft)
1 000 m
(3 300 ft)
1 250 m
(4 125 ft)
Multiple Monitor Connection
Connect the VIDEO OUT connector on the monitor to the
VIDEO IN connector of an other monitor with a coaxial
cable to monitor the same video on multiple monitors.
Up to 10 monitors in total can be connected in a series
before signal loss occurs. The total cable length should not