Patton electronic 2150 Switch User Manual


 
10
Figure 2. Model 2150 standalone rear panel
3.1 CONNECTING THE TWISTED-PAIR LINE INTERFACE
The Model 2150 supports communication between two peer Ethernet
LAN sites over a distance of up to 5,000 (1.5 km) over 24 AWG (0.5
mm)
twisted-pair wire.
Note Actual distance and link performance may vary depending on
the environment and type/gauge of wire used.
Follow the steps below to connect the Model 2150 CopperLINK Inter-
faces.
Note The Model 2150 units work in pairs. One of the units must be
configured as a (L) Local unit, and the other unit must be config-
ured as a (R) Remote unit. It does not matter which end is the L
and which is the R. The link is always initiated by the R unit. As
long as the L unit is powered on, the R unit can establish a link
by being powered on or by having its power reset.
The Interconnecting cables shall be acceptable for
external use and shall be rated for the proper applica
-
tion with respect to voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability.
Line
Power
Made in the USA
Ethernet
Power
jack
Dual 10/100
Ethernet ports
CopperLINK
twisted-pair
RJ-45 interfac
e
2 1