11
1. To function properly, the two Model 2173s must be connected
together using twisted-pair, unconditioned, dry, metal wire, between
19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through
signal equalization equipment are not acceptable.
2. The Model 2173 is equipped with an RJ-45 interface jack that can be
used on the CopperLINK interface. The CopperLINK interface is a
two-wire interface. Observe the signal/pin relationships on the Model
2173's CopperLINK interface jack.
The RJ-45 connector on the Model 2173's twisted pair interface is polar-
ity insensitive and is wired for a two-wire interface. The signal/pin rela-
tionship is shown in Figure 3.
Figure 3. Model 2173 (RJ-45) twisted pair line interface.
3.2 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE
The shielded RJ-45 ports labeled Ethernet are the Auto-
MDIX10/100Base-T interface. These ports are designed to connect
directly to a 10/100Base-T network.
Figure 4 shows the signal/pin rela-
tionships on this interface. You may connect this port to a hub or PC
using a straight through or crossover cable that is up to 328 ft long.
The Interconnecting cables shall be acceptable for
external use and shall be rated for the proper applica
-
tion with respect to voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability.
1 (no connection
)
2 (no connection
)
3 (no connection
)
4 (RING)
5 (TIP)
6 (no connection
)
7 (no connection
)
8 (no connection
)
1
2
3
4
5
6
7
8
CAUTION