Patton electronic 576 Surge Protector User Manual


 
APPENDIX B
INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) COM-
PLIANCE
Meets IEC standards 801.2, 801.4 and 801.5 (CE Mark)
Effective January 1996 the European Economic Community will
require that all electronic devices be tested and comply with all appli-
cable International standards relating to the product type and category
of use. Electromagetic Compatibility Directive 89/336/EEC specifically
addresses communication line surge protection devices, since con-
formity to immunity standard EN50082-1:1992 is mandatory. The
EN50082-1:10992 standard incorporates International Organization for
Standardization (ISO) publications 801.2 and 801.4, which describe
Electrostatic Discharge and Electrical Fast Transient requirements.
ISO 801.5 describes Surge Immunity Requirements and is expected to
be adopted as a mandatory requirement under EN50082-1 by the
Technical Committee. in 1996. Any protector sold into the international
community must meet these standards. This device has been tested*
and found to comply with these standards as evidenced by its CE
mark.
*Note: All test results are for the Model 57x/58x
alone
, not including
any external patch cables that are connected to the unit.
APPENDIX A
SPECIFICATIONS
Environment: Category-5 Interfaces that utilize the RJ-45
connector, including RS-422, 423, 10Base-
T, Token Ring, Fast Ethernet, 100Base-T,
100Base-T4 and ATM
Connectors: RJ-45 Female
Response Time: Clamped to 13V after 0.1µS
Characteristic Impedance: 100 Ohms
NEXT Loss (worst pair): Better than -40 dB at 100 MHz
Surge Clamping Voltages: Model 57x: 13 V max with 1 KV Input;
Model 58x: 15 V max with 2 KV Input
Surge Rating: IEC 801.5 Standard Level
DC Clamping Voltages: Common Mode to Gnd, 7.5 V (each line)
@ 50 mA; Differential mode, 8.1 V (per
pair) @ 50 mA
Insertion Loss: Less than 0.4 dB (including connector) at all
frequencies
Return Loss: Better than 14 dB on both models
Group Delay: None, 1 MHz to 100 MHz
Series Resistance: Less than 400 milliohms
Grounding: External ground strap provides separate
unit-ground to chassis-ground contact
PC Board Dimensions: 7.0” x 3.0”
Actual Panel Dimensions: 3.47” x 19.0” x 1.1”
Standard Temperatures: 0 - 50
0
C/32 - 122
0
F
Flame Retardance: Plastic cases meet UL 94-V0 standard
7 8
Class
1 1.0 kV
24 A
2 1.0 kV
24 A
3 2.0 kV
48 A
4 (n/a)
(n/a)
5 4.0 Kv
95 A
Wave (1.2 x 50 µs)
Forms (1.2 x 50 µs)
IEC 801-5 Threat Levels as a Function of Class
Sym. Lines Coupling Mode
Line-GND, Zs=42 Ohms
Figure B-1. IECThreat Levels as a Function of Class.