Peerless Industries PRS-UNV-S Projector Accessories User Manual


 
ISSUED: 09-19-05 SHEET #: 055-9441-5 10-31-08
Visit the Peerless Web Site at www.peerlessmounts.com
6 of 12
For customer care call 1-800-729-0307 or 708-865-8870.
Place projector mount assembly (A) on ceiling as a
template and mark the center of the two mounting
holes. Drill two 1/4" (6 mm) dia. holes to a minimum
depth of 2.5" (64 mm). Attach projector mount
assembly (A) using two concrete anchors (D), two
flat washers (F), and two #14 x 2.5" wood screws (C)
as shown in Illustration A and 1, 2, and 3.
Note: Mounting slots on projector mount assembly
allow for 30° (±15°) of rotation before fully securing
wood screw.
Tighten wood screws (C) using 3/8" (10 mm) socket
wrench or phillips screwdriver until projector mount
assembly (A) is firmly attached.
Skip to step 5.
C
Illustration A
Installation to Concrete Ceilings
A
F
D
FRONT OF
MOUNT
Tighten wood screws firmly, but do not overtighten.
Overtightening can damage the screws, greatly
reducing their holding power.
Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
3
Always attach concrete anchors directly to load-
bearing concrete.
Never attach concrete anchors to concrete covered
with plaster, drywall, or other finishing material. If
mounting to concrete surfaces covered with a finishing
surface is unavoidable, the finishing surface must be
counterbored as shown below. Be sure concrete
anchors do not pull away from concrete when tighten-
ing screws. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer (not
UL approved).
WARNING
concrete
surface
1
3
2
D
Drill holes and insert anchors (D).
Place plate (A) over anchors (D) and secure with screws (C).
Tighten all fasteners.
A
D
C
CUTAWAY VIEW
INCORRECT
CORRECT
plaster/
dry wall
concrete
concrete
plaster/
dry wall
A
A
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
WARNING