Calibrating I/O
176 IOLAN DS1/TS2 User’s Guide, Version 3.4
Calibrating I/O
All I/O channels are factory calibrated and should not need recalibration during initial use. However
should calibration be required, you can recalibrate in DeviceManager or WebManager. In
DeviceManager, you calibrate the I/O channel(s) by selecting
Tools, I/O Channels, Calibrate. In
WebManager, you calibrate the I/O channel(s) by selecting
I/O Channels, Calibrate.
Calibrating Analog Input
To calibrate an Analog input channel, read the section that applies to the type of input you are
calibrating. Note that calibration will be done for the active channel configuration; for example, if
Channel A1 is set to voltage, you cannot calibrate it for current. The voltage range configured for this
channel will also dictate what is being calibrated. For example, if this channel is configured for a
range of +/-10V, calibrating this channel will calibrate all channels which are configured for +/-10V.
During the calibration process, you will be asked to apply the minimum and maximum configured
range value to the channel; for example, to calibrate for voltage +/- 10V, you will be prompted to first
apply -10V and then +10V to the channel.
Also, you cannot actively calibrate disabled channels (although, for Voltage, if you enable the
channel and then set it for a range that has already been calibrated for another channel, it will also be
calibrated).
Calibrating Voltage
When calibrating the IOLAN Analog input for voltage, you will need a calibration meter that is better
than .1% volts precision. When you calibrate one channel, all voltage channels are automatically
calibrated for that range; if another channel is set for a different range, you will need to calibrate that
channel separately, but all channels that use that range are also automatically calibrated.
Calibrating Current
When calibrating the IOLAN Analog input for current, you will need a calibration meter that is better
than .1% current precision. Each channel needs to be calibrated individually.
Calibrating Temperature Input
To calibrate an Analog (Temperature) input channel, read the section that applies to the type of input
you are calibrating. Note that calibration will be done for the active channel configuration; for
example, if Channel A1 is set to thermocouple, you cannot calibrate it for RTD. During the
calibration process, you will be asked to apply the minimum and maximum range value to the
channel in either mV or Ohms; for example, to calibrate for thermocouple J 0 to 760C, you will be
prompted to first apply -80mV and then +80mV to the channel.
Also, you cannot actively calibrate disabled channels (although if you enable the channel and then set
it for the type of thermocouple or RTD that has already been calibrated on another channel, it will
also be calibrated).
Calibrating Thermocouple
When calibrating the IOLAN Analog input for thermocouple, you will need a calibration meter that is
better than .15% accuracy. When you calibrate one channel, all thermocouple channels are
automatically calibrated for that range; if another channel is set for a different range, you will need to
calibrate that channel separately, but all channels that use that range are automatically calibrated.