Perle Systems S-1110P Switch User Manual


 
Perle PoE/PoE+ Ethernet Media Converter
Installation Guide
15
Down Up
PSE enabled
Legacy device
detection
Down Down PSE disabled
These switches must be set in order to enable the power sourcing
function and to indicate the type of device detection required. If the
device type is unknown, the default should be used as per
IEEE802.3af/at standards.
Enabled: When enabled, the media converter will perform Power
Sourcing Equipment (PSE) functions as per IEEE802.3af (POE) or
802.3at-2009 (POE+) standards.
Disabled: When disabled the media converter will not perform
PSE functions.
PD Power Reset 1 (Switch 3)
PD Power Reset 2 (Switch 6) (dual copper
models only)
Switch Position Mode
Up (default) Disabled
Down Enabled
Disabled: When disabled, the loss of fiber link has no effect on
PSE power to the PD device.
Enabled: When enabled, if the media converter detects loss of link
on any fiber port it will turn off PSE output power to the PD device
connected to copper port 1. After 2 seconds, the media converter
will restore power to the PD and the power will remain on until one
of the fiber links transitions from the link up to link down state.
Disabled: When disabled the media converter will not perform
PSE functions.
Fiber Redundancy (Switch 7)
Dual fiber models only
Switch Position Mode
Up (default) Disabled