Planet Technology EV-401M Switch User Manual


 
EV-401M / EV-401S User's Manual
13
Blinking
Amber
A collision occurs when two stations within a
collision domain attempt to transmit data at the
same time. Intermittent flashing amber of the
collision LED is normal; the contending
adapters resolve each collision by means of a
wait-then-retransmit algorithm. Frequency of
collisions is an indicator of heavy traffic on the
network.
Mode slide switch* (for EV-401M only)
SYM
It provides 10M upstream and 10M downstream. It will
extend up to 1.2km (4000ft) with AWG 26(0.4mm)
telephone wire. The distance will change by the quality
of cable. (default mode)
ASYM* It provides 3M upstream and 10M downstream. It will
extend up to 1.35km (4500ft) with AWG 26(0.4mm)
telephone wire. The distance will change by the quality
of cable.
*Note 1: Power off and on the converter to make the mode take
effect.
*Note 2: When run on this mode, the VDSL connection
can coexist with other HomePNA connections
over the same telephone wire.
2.2 Rear Panel
The rear panel of the Converter is shown as below
The rear panel of the Converter indicates a AC inlet power
socket, which accepts input power from 100 to 240VAC,
50-60Hz 1.0A Max.