Polycom RMX 2000 Hardware Guide
1-15
Replacing a Functional MPM Module
Use the following procedure to replace a faulty MPM Module types F
or H:
1 Ensure that power switch to the RMX is turned OFF (O).
2 Unscrew the screws on the front panel of the RMX that secure the
MPM Module.
3 Use the metal ejectors to pull the MPM Module out of its slot in the
Backplane.
4 Carefully slide the MPM Module out through the front panel.
5 Slide in the replacement MPM Module.
6 Push the MPM Module firmly into the Backplane, making sure it is
properly seated in its slot.
7 Ensure that the metal ejectors are fully retracted into their housings.
8 Tighten the screws on the front panel of the RMX that secure the
MPM Module.
9 Turn ON the RMX.