POSIFLEX Business Machines CR400X Cash Register User Manual


 
4
3). Set S1 for security code to open cash drawer. In normal practice, the security code is
suggested to be a non-displayable ASCII character. For. example, a hexadecimal
number between 01 to 1F. Please refer to rear panel illustration below.
CR4001/ 4101/ 4211/ 4002/ 4102/ 4212/ 4003/ 4103/ 4213 Rear panel illustration.
S1 Set security code. (Default Setting: BIT 1,2,3 OFF and BIT 4,5,6,7,8 ON. Security
code is 07H)
BIT 1 2 3 4 5 6 7 8
Number to be added to the
security code if OFF.
1 2 4 8 16
32
64
128
S2 BIT1 ON and BIT2 OFF to receive security code via Pin2 of P4 (DB9F).
BIT1 OFF and BIT2 ON* to receive security code via Pin3 of P4 (DB9F).
BIT3 OFF and BIT4 ON for dedicated RS-232C.
BIT3 ON and BIT4 OFF* for non-dedicated RS-232C.
(*denotes factory default setting)
CR4004 / 4104 / 4214
1). Open the PC case. Put the metal
bracket with power connector into one
of the I/O windows.
2). Connect the cable to the HDD type
power connector of PC power supply.
See illustration below. Then close the
PC case.
3). Connect the DB-9 connector to the
computer's serial port of COM1 (or
COM2). Connect the 4P phone plug connector to the added I/O bracket. See below
illustration.
AC 12V I/P
SERIAL O/P (DB9M)
SERIAL I/P (DB9F)
PARALLEL O/P (DB25F)
PARALLEL I/P (DB25M)
1
8
4
1
GROUND
S2
S1
Switch is ON when pushed up
616P PHONE JACK
POWER CORD