802.3af modular installed base considerations
802.3af minimum PSE voltage: 44V
Modular switches
44V power supply is deployed with chassis
Customer expectation: 802.3at-blades added to 802.3af-chassis
51V minimum at PSE Æ Boost converter MUST be placed on blade
More power dissipation at blade
More components added to crowded blade