Powerware 3105 Switch User Manual


 
11 22 33
44 55 66
77 88 99
77 88 99
SPECIFICATIONS
Model Numbers
350 VA / 210W
500 VA / 300W
700 VA / 420W
Capacity
TROUBLESHOOTING
Symptom
Possible Cause
Action to Take
UPS will not turn on
SERVICE AND SUPPORT
MA6B412005(2005/01/12)
700VA model (12V- 7AH battery)
STATUS INDICATORS:
The UPS provides both visual and audible status indicators. Visual
indicators consist of two LEDs to represent the following conditions:
On utility power operation
On battery power operation
UPS fault/alarm
LED & Alarm Status Table
UPS Status
Green LED
Red LED Buzzer
Self-test
AC
(Utility)
Mode
DC
(Battery)
Mode
Charging
Charge Off
Low Battery (Self-test)
Over Load
Normal
Over Load
Low Battery
Short / Fault
Over-Battery / Battery Fault
Blink 1(by turns)
ON
ON
ON
ON
ON
Blink 2
Blink 2
Blink 2
X
X
X X
X X
X
Blink 2
Blink 2
Blink 2
Blink 2
Blink 2
B1
B2
B4
B1
B4
B3
ON
B5
Notes:
Blink 1: ON 0.5 seconds / OFF 0.5 seconds.
Blink 2: ON 0.25 seconds / OFF 0.25 seconds.
B1: 1 beep / 5 seconds, ON 0.25 seconds / OFF 4.75 seconds.
B2: 3 beeps / 30 seconds, ON 0.25 seconds / OFF 0.25 seconds 3 times, 28.5 seconds OFF.
B3: 2 beeps / 5 seconds, ON, 0.25 seconds / OFF 0.25 seconds 2 times, 4 seconds OFF.
B4: ON 0.5 seconds / OFF 0.5 seconds.
B5: 3 beeps / 5 seconds, ON 0.25 seconds / OFF 0.25 seconds 3 times, 3.5 seconds OFF.
PW3105 350A
PW3105 500A
PW3105 700A
Nominal Input Voltage
Nominal Output Voltage
Frequency
Total 6 Outlets
240Vac
240Vac
50 / 60 Hz auto sensing
3 Battery Backup & Surge Protection
3 Surge Protection only
Lighting / Surge Protection
Transfer Time to Battery/AC
Battery Type
476 Joules
6ms Typical
Maintenance free, Sealed and leak proof lead-acid
battery
350 / 500 VA: 12V 5 AH
750 VA: 12V 7 AH
Battery Specification
Typical Backup Time
Internet / Phone / Fax Protection
Short Circuit Protection
Communication Port
Operating Temperature
Operating Relative Humidity
3 minutes minimum at full rated load
RJ11
Circuit Breaker
USB
0 C to 40 C
0 to 95% non-condensing
Storage Temperature
-15 C to 50C
Net Weight
350VA - 4.8 kg
500VA - 5.5 kg
700VA - 7 kg
Dimensions (W x D x H)
280 x180 x115mm
* Due to continuing product improvement programs, specifications subject to change
without notice.
The battery is disconnected
or utility power is not
available at the wall outlet.
Input Circuit Breaker has
tripped.
Connect the battery (see Connect
Battery) and ensure power is
available at the wall outlet.
Reduce the amount of equipment
plugged into the outlets of the UPS.
Next, reset the circuit breaker by
pushing the plunger back in.
UPS is making a
continuous sound and
the “Overload” indicator
is lighted.
Turn off the UPS and reduce the
amount of equipment connected to
these outlets.
The “Battery Backup &
Surge Protection” outlets
are overloaded.
Removed all connected equipments
from the UPS and charge the battery
at least 8 hours. During this charging
period, turn off the UPS to prevent
unnecessary discharging.
Call for service or you can replace
the battery by ordering one from
your dealer.
The battery is not fully
charged.
Battery is getting older.
UPS does not provide
expected runtime.
Reduce the amount of equipment
plugged into the outletsof the UPS.
Tryreducing the load byremoving
one piece ofequipment at a timeto
determine if theproblem continues.
The UPS will turn off when the
battery has been depleted during
an extended power outage. Allow
the UPS to re-charge the battery,
before continuing on battery opera
tion.
Ensure the equipmentthat is to be
protected from apower outage is
plugged into the“Battery Backup &
Surge Protection” outlets.
Contact PowerwareTechnical
Support
The UPS is overloaded.
The UPS has exhausted
its available run time.
Equipment is connected
to the “surge Protection”
outlets.
The UPS may require
service.
When utility power fails,
connected equipment
loses power
Please have the following information ready:
Model number and serial number
Symptoms of failure or problem
Customer contact information
For additional information and to register your warranty, please visit
www.powerware.com.au
Register your warranty within 30 days and receive an extended pro-rated
warranty and load protection guarantee.
Eaton Power Quality Pty Ltd
119-127 Wicks Road,
North Ryde NSW 2113
For service and support please call your local distributor or the Powerware
Australia National Service and Repair Centre.
Australia freecall 1300 303 059.