Powerware 5105 Power Supply User Manual


 
Technical Specifications
1
The lead-acid batteries typically used in a
UPS are considered viable as long as they
can maintain backup times of at least half
that of new batteries. The illustration to the
right shows that batteries that are constantly
trickle charged (as are virtually all other UPS
batteries on the market today) reach the end
of their useful life in less than half the time
of batteries charged using ABM. ABM uses a
patented three-stage charging technique that
not only doubles battery service life, but
also optimizes battery recharge time and
provides up to a 60-day advanced notifi-
cation of pending end of useful battery life.
Advanced Battery Management (ABM™) Technology Doubles Battery Service Life
Data based upon tests performed by an independent battery manufacturer
1. Due to continuing product improvement programs, specifications are
subject to change without notice.
EL E C T R I C A L IN P U T
Voltage 120 and 230 Vac nominal; see Model Selection Guide for
user-selectable voltages
Online -30%, +20% for nominal voltages; user-selectable
Voltage Range extended range of -35%, +20%
Nominal Input 50/60 Hz; auto-selection
Frequency
Connections See Model Selection Guide
EL E C T R I C A L OU T P U T
Power Levels 450, 700, 1000, and 1500 VA
Online Efficiency 96%
Online Regulation -10%, +6%; within Computer Business Equipment
Manufacturers Association’s Guidelines (-15%, +10%
using extended range)
On Battery ±5% RMS
Regulation
Voltage Wave Shape Quasi-sine wave
(on battery)
No Load Sleep Mode Outputs are turned off if <5% load is detected (selectable)
Connections See Model Selection Guide
Interconnecting 2 ea. IEC-320 (10 A); 230 Vac models only
Cords(cabinet)
Interconnecting 4 ea. IEC-320 (10 A)
Cords(rack)
Backup Time See Battery Run Times table
Battery Charging <4 hrs to 90% usable capacity
Battery Type Sealed, maintenance-free lead-acid
Start-On-Battery Startup with UPS batteries in absence of utility power
IN D I C AT O R S A N D CO N T R O L S
Serial Intelligent serial communication to provide alarms
Communication with history, measured parameters, selftest, and many
other features.
Front Panel Ergonomic indicators including wiring fault, battery
Interface LEDs service, communication operation, system normal; bar
graphs for input level, battery charge level, % load
Digital Input/Output Remote On/Off
PH Y S I C A L
Dimensions and See Model Selection Guide
Weight
Surge Suppression High energy 6500 peak Amp
Audible Noise Less than 45 dB
Operating Temp 0°C–40°C (32°F–104°F)
UL tested at 25°C (77°F)
Operating Humidity 5 to 95% non-condensing
Operating Altitude Up to 10,000 feet above sea level
Conformance IEEE 446, NEMA PE 1;
Standards ANSI C62.41; FCC Class A and B, EN50091-2
Class B, NSTA and others
Safety Standards UL 1778, CSA C22.2, and European standard
EN 50091-1
Network Transient In and out RJ11 jack for telephone/modem
Protector protection (120 Vac models only) or RJ45 for
10Base-T network cable; UL497A tested
PO W E R PR O T E C T I O N
Series 5 Protection against power failures, power surges,
Protection power sags, brownouts, line noise, and a degree of
protection against other power problems
Battery Level
Front Panel Display
Load Level
C o m m u n i c a t i o n s
Off/Standby
Button
Alarm Silence/
Self-test Button
Input Voltage
Level
Site Wiring Fault
ABM (up to
60-day notice
for battery
service)
On Button
(Start-on-battery)