Powerware 9355 Power Supply User Manual


 
With advances in miniaturization and processing power, a single
rack of equipment demands more power than ever—and more
equipment will be served by dual cord power supplies. It’s a chal-
lenge to provide power protection for expanding loads in shrink-
ing spaces.
Fortunately, technology advancements have also raised the den-
sity per square foot of power protection systems. The Powerware
9155 and new Powerware 9355 uninterruptible power systems
(UPSs) deliver premium levels of efficiency, reliability and flexibil-
ity—all in a sleek tower half the size of most competitor units on
the market today.
These double-conversion, online UPSs resolve all nine common
utility power problems and supply clean, continuous power to
all connected equipment. Even when presented with the most
severe power problems, power output remains stable. And if the
utility power goes out altogether, there is no delay transferring to
backup power.
These capabilities make the Powerware 9155 and Powerware
9355 ideal for protecting essential data center, communications
and electrical engineering infrastructures in corporate, telecom,
healthcare, banking, public sector and industrial applications.
Features
Protects connected equipment from all nine of the most
common power problems with true online, double-conversion
topology
Delivers maximum power density in a compact tower
design, only 12” wide and 33” deep, including batteries
Provides more real wattage in less space with a 0.9 power
factor—protecting more equipment for every utility dollar,
and leaving more room for expansion
Delivers extra capacity or redundancy through patented
Powerware Hot Sync
®
paralleling of multiple modules
Significantly increases battery life through microprocessor-
controlled ABM
®
technology
Provides 0.99 power factor and generator friendly <5% total
harmonic distortion using an active IGBT rectifier to control the
input power factor
Ensures data and system integrity with complete power man
-
agement software for remote monitoring, management, and
shutdown
Provides investment protection and peace of mind with an
Eaton factory limited warranty, technical support, and optional
service plans
Product Snapshot
Technology: 9155: Split-phase double-conversion
online UPS
9355: Three-phase double-conversion
online UPS
Power Rating: 9155: 8 kVA, 10 kVA, 12 kVA, 15 kVA
at 0.9 power factor
9355: 10 kVA and 15 kVA
at 0.9 power factor
Input Voltage: 9155: 200–240 Vac with Neutral or with
optional input isolation transformer
9355: 208V/120V or 220V/127V
Output Voltage: 9155: 100/200, 110/220, 120/240 Vac
180° phase displacement; 120/208,
127/220 Vac 120° phase displacement
9355: 208V/120V or 220V/127V
480:120V/208V or 600:120/208 with
input isolation transformer
(at 60 Hz only)
Frequency: 50/60 Hz auto-sensing
Dimensions: Two-high configuration:
32.2” H x 12.0” W x 32” D
Three-high configuration:
47.8” H x 12.0” W x 33.5” D
Configuration: Small-footprint tower, black
Battery Backup: 9155: Up to 29 minutes typical, extendable
up to four hours
9355: Up to 22 minutes typical, extendable
up to three hours
See Battery Back-up Times chart
Product Introduction