ENTERING THE INTERFACE SETUP MENU
The setup menu for interface parameters is the second setup menu. To enter this menu, first
take the printer offline (refer to the ONLINE button described earlier). Then press and hold
the SETUP button approximately two seconds until “Setup: INTERFACE” is displayed and
the bell beeps twice to indicate that the second menu has been entered (Note that “Setup:
FORMS” will be displayed and the bell will beep once before the interface menu is
displayed. Continue to hold the button to pass through this menu and proceed to the interface
menu). At this time you are able to view and/or edit the values for the various interface
functions as listed below. While you may select functions with either the FUNCTION UP or
FUNCTION DOWN buttons, they are listed here in the order of function up.
The factory default settings are indicated by an asterisk (*).
Function Possible Values Description
Mode: n = Test, ANSI X3.64,
Epson*, Bar Codes,
Proprinter, LA-120, TTY,
Printek, Barberpole, or Hex
Dump
Selects the current emulation mode,
barberpole mode, or hex dump
mode. The test mode is for factory
use only.
I/O: Parallel*, Serial, or CX/TX
(optional)
Selects the active I/O port. If the
CX/TX interface is installed, then
CX/TX also selects the parallel
port. Not available when the RS-
422 interface is installed.
Baud Rate: 150, 300, 600, 1200, 2400,
4800, 9600*, or 19200
Selects the baud rate for the serial
interface. Not available when
Parallel or CX/TX is selected.
Data Bits: 7 or 8* Selects the number of data bits in
the serial character frame and the
number of significant data bits in
each character received via all other
interfaces.
Parity: None*, Ignore, Odd, or
Even
Selects the parity checking
requirements for the serial data bits.
Not available when Parallel or
CX/TX is selected.
Busy: Low* or High Selects the polarity of the busy
signal (pin 11 of the RS-232C
interface). Available only when the
RS-232C interface is installed and