Proview 786PF Computer Monitor User Manual


 
D
Background
White
Balance
Adjust
Color Analyzer
R.G.B off
(68KHz,1024x768)
1. Set the contrast to MAX.,Brightness to Y=0.7
set color is 9300
°
K
using the OSD.
2. Set the OSD to COLOR of sub menu and press
knob.
3. Make the adjustment R.G.B BIAS low light to
the value shown at right by using encorder.
Y = 0.7
±
0.1FL
x = 0.283
±
0.01
y = 0.297
±
0.01
E
White
Balance
Adjust
Color Analyzer
Oscilloscope
Cathode G
3” block
(68KHz,1024x768)
1. Move the OSD to the R.G.B. DRIVE.
2. Move the OSD to the G DRIVE and make the
adjustment to the value shown at right by using
encorder.
3. Move the OSD to the R,B-DRIVE and make the
Adjustment to the value shown at right by using
Encorder.
37V
P-P
x = 0.283
±
0.01
y = 0.297
±
0.01
F
ABL
Adjust
Color Analyzer
Full White
(64KHz,1280x1024)
1. Set the contrast to MAX.,Brightness to MAX.
2. Make the adjustment to the value shown at right
by adjustment ABL on the OSD menu.
Y = 33FL
G
Other
Function
Seting
Full White
(64KHz,1280x1024)
1. Set the FREQ. to 87
2. Set the OSD to MAG
3. Set the BURN to Disable
4. Set the TIME to 15
5. Set the DEFO to TDA9113/9112
H
Dynamic
Focus
Adjust
Oscilloscope
FBT Pin14
Full White
(31.5KHz,640x480)
1. Set the contrast to MAX.,and adjustment
Brightness to the raster just appear.
2. Make the adjustment to the value shown at right
by adjust the VF on the OSD menu.
3. Make the check to the value shown at right by
adjust the HF on the OSD menu.
VF :
140
±
10V
P-P
HF :
430
±
10V
P-P
I
Purity
Adjust
Magenta color
(31.5KHz,640x480)
1. Adjust the purity magnet is in magneta color.
2. Turning two overlapping pawels in opposite
directions.
3. Move them until they are at the same angle,
9 o’clock and 3 o’clock respectively.
ITEM
Program Menu.
Test Meter
Test Point
Pattern
Operation
Adjusting
Value