PSC LR, XLR Scanner User Manual


 
User’s Guide
9
Figure 5. Depth of Field (LR)
NOTE
In the context of the illustration below, a "mil" repre-
sents the minimum bar code element width. Mea-
surements are based on LR models set with the a
14° scan width (as opposed to the alternate Full
Angle setting of 28°). Reference the PowerScan Pro-
gramming Manual for more information about the
Half Angle feature.
Specifications are subject to change without notice.
Depth of Field
Paper Labels (LR decoded model, Code 39)
0
40 mil
20 mil
15 mil
7.5 mil
CENTIMETERS
FEET
FRONT OF SCANNER
10
12345
20 30 40 50 60 70 80 90 100 110 120 130 140 150 160
6789
170 180 190 200 210 220 230 240 250 260 270 280
10 mil
55 mil
Reflective Labels (LR decoded model, Code 39)
70 mil
55 mil
40 mil
CENTIMETERS
FEET
FRONT OF SCANNER
6706506306105905705505305104904704504304103903703503303102902702502302101901701501301109070503010
1
0
2345678910 11 12 13 14 15 16 17 18 19 20 21 22
100 mil