14 QS2500
IBM Options
IBM 46xx Code 39 Conversion
This feature enables/disables the scanner’s ability to set the symbology
identifier for the specified symbology to Code 39 before sending the label
data to an IBM host. This applies to: Code 128, Code 93 and Codabar for
IBM Port 5B; Code 93 and Codabar for IBM Port 9B.
IBM-USB Device Type
The IBM-USB protocol allows for the scanner to be identified as one of
two different types of barcode scanners. Depending on what other scan-
ners you may already have connected to a IBM-USB POS, you may need
to change this setting to enable all scanners to communicate. Options are:
• Table Top Scanner
• Handheld Scanner
IBM Maximum Host-Transmitted Message Length
Specifies the maximum number of data characters allowed in messages
transmitted to an IBM host.
NOTES
This feature is for IBM port 5B and IBM port 9B.
NOTES
This feature applies only to the IBM USB interface.
NOTES
If this configuration item is set to zero, there is no general length
limit imposed on data being transmitted to the host.