Q-Logic 9080 Switch User Manual


 
5
Flow control = XON/XOFF
Step 2. Power up the switch.
Step 3. To change the switch default IP address enter:
setChassisIpAddr -h ipaddress -m netMask
where -h ipaddress is the new IP address in dotted decimal (i.e., xxx.xxx.xxx.xxx) format, and -m netMask
is the new subnet mask in dotted decimal (i.e., xxx.xxx.xxx.xxx) format.
Step 4. To change the switch default gateway IP address enter:
setDefaultRoute -h ipaddress
where -h ipaddress is the new default gateway IP address in dotted decimal (i.e., xxx.xxx.xxx.xxx) format.
Using Telnet or SSH
Step 1. Power up the switch.
Step 2. Connect a Category 5 or 6 (Cat 5/6) Ethernet cable to the RJ-45
connector on the switch. Connect the other end of the Cat 5/6 to a OOB LAN
workstation.
Step 3. Access the switch with the following command:
telnet 192.168.100.9
Step 4. The system prompts for a user name. In order to change the IP
address and default gateway, the user must be logged in as the
administrator. At the prompt enter:
admin
Step 5. The system prompts for a password. At the prompt enter:
adminpass
The system responds with:
Welcome to the SilverStorm 9080 CLI. Type 'list' for the list of
commands.
Step 6. To change the switch default IP address enter:
setChassisIpAddr -h ipaddress -m netMask