Raritan Computer P2-USTIP2 Network Card User Manual


 
6 USTIP USER GUIDE
Windows 2000 / ME Settings
On target servers running Microsoft Windows 2000 / ME, set the mouse pointer acceleration to
“none” and the mouse motion speed exactly to the middle speed setting. These parameters are
found in: Start Settings Control Panel Mouse Motion.
Windows 95 / 98 / NT Settings
On target servers running Microsoft Windows 95 / 98 / NT, set the mouse motion speed to the
slowest setting in Start Settings Control Panel Mouse Motion.
Linux Settings
On target servers running Linux graphical interfaces, set the mouse acceleration to exactly 1 and
set threshold to exactly 1.
As mentioned above, please ensure that each target server running Linux is using a resolution
supported by USTIP at a standard VESA resolution and refresh rate. Each Linux target server
should also be set so the blanking times are within +/- 40% of VESA standard values.
To check for these parameters:
Go to the Xfree86 Configuration file XF86Config
Using a text editor, disable all non-USTIP supported resolutions
Disable the virtual desktop feature, which is not supported by USTIP
Check blanking times (+/- 40% of VESA standard).
Restart computer
Note: In many Linux graphical environments, the command CTRL+ALT+ + [plus sign key] will
change the video resolution, scrolling through all available resolutions that remain enabled in
the XF86Config file.
Sun Solaris Settings
All target servers must be configured to one of the display resolutions supported by USTIP. The most
popular supported resolutions for Sun machines are:
1024x768@60Hz
1024x768@70Hz
1024x768@75Hz
1024x768@85Hz
1152x900@66Hz
1152x900@76Hz
1280x1024@60Hz
Target servers running the Solaris operating system must output VGA video (H-and-V sync, not
composite sync). To change your Sun video card output from composite sync to the non-default
VGA output, first issue the Stop+A command to drop to bootprom mode. Then, issue the
command:
setenv output-device screen:r1024x768x70
to change the output resolution. Issue the “boot” command to reboot the server.
Alternatively, you may contact your Raritan representative to purchase a video output adapter.
13W3 Suns with composite sync output require APSSUN II Raritan guardian for use with USTIP.
HD15 Suns with composite sync output require 1396C Raritan converter to convert from HD15
to 13W3 and an APSSUN II Raritan guardian converter to support composite sync. HD15 Suns
with separate sync output require an APKMSUN Raritan guardian for use with USTIP.