Renesas FP-144 Computer Hardware User Manual


 
Fasten the user system interface cable head to the IC socket for a FP-144 package on the user system
with the four screws (M2
x 10 mm) provided. Each screw should be tightened a little at a time,
alternating between screws on opposing corners. Take special care, such as manually securing the
IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening
the screws or twisting the components.
User system
Pin 1
Cable head
IC socket
(NQPACK144SD
manufactured by
Tokyo Eletech Corporation)
Screws (M2 x 10mm)
Figure 4 Connecting User System Interface Cable to User System