Renesas H8/36057 Computer Hardware User Manual


 
3
1.3 Operating Voltage and Frequency Specifications
Table 1.3 shows the MCU operating voltage and frequency specifications supported by the E6000.
If the E6000 is used in an environment that exceeds the operating voltage range and operating
frequency range guaranteed for the MCU operation, normal emulator operation is not guaranteed.
Table 1.3 Operating Voltage and Frequency Specifications
No. MCU Types Operating Voltage (V)
Operating Frequency
(φ) (MHz)
1 H8/36037 Series
H8/36057 Series
3.0-5.5
4.0-5.5
2-10
2-20
NOTE
For details on the operating voltage and frequency
specifications, refer to the MCU hardware manual.