Renesas HD74LV1G66A Switch User Manual


 
HD74LV1G66A
REJ03D0069-0700 Rev.7.00, Mar 21, 2008
Page 4 of 8
Electrical Characteristics
T
a
= 25°C T
a
= –40 to 85°C
Item Symbol V
CC
(V)
Min Typ Max Min Typ Max
Unit
Test
Conditions
1.65 to 1.95 — — — V
CC
×0.75 — —
2.3 to 2.7 V
CC
×0.7 — —
3.0 to 3.6 V
CC
×0.7 — —
V
IH
4.5 to 5.5 V
CC
×0.7 — —
1.65 to 1.95 — — — V
CC
×0.25
2.3 to 2.7 V
CC
×0.3
3.0 to 3.6 V
CC
×0.3
Input voltage
V
IL
4.5 to 5.5 V
CC
×0.3
V Control input only
1.8 — — 0.25 —
2.5 — — 0.30 —
3.3 — — 0.35 —
Hysteresis
voltage
V
H
5.0 — — 0.45 —
V V
T
+
– V
T
1.65 — 120 360 450
2.3 — 60 180 — — 225
3.0 — 50 150 — — 190
On-state switch
resistance
R
ON
4.5 — 40 75 — — 100
V
IN
= V
CC
or GND
V
C
= V
IH
I
T
= 1 mA
1.65 — 700 1100 — 1400
2.3 — 250 500 — — 600
3.0 — 100 180 — — 225
Peak on
resistance
R
ON (P)
4.5 — 50 100 — — 125
V
IN
= V
CC
to GND
V
C
= V
IH
I
T
= 1 mA
Off-state switch
leakage current
I
s (OFF)
5.5 ±0.1 — ±1.0 µA
V
IN
= V
CC
,
V
OUT
= GND
or V
IN
= GND,
V
O
= V
CC
, V
C
= V
IL
On-state switch
leakage current
I
s (ON)
5.5 — ±0.1 — ±1.0 µA
V
IN
= V
CC
or GND
V
C
= V
IH
Input current I
IN
0 to 5.5 ±0.1 ±1.0 µA V
IN
= 5.5 V or GND
Quiescent
supply current
I
CC
5.5 — — 10 µA V
IN
= V
CC
or GND
Control input
capacitance
C
IC
— — 3.5 — — — pF
Switch terminal
capacitance
C
IN / OUT
— — 4.0 — — — pF
Feed through
capacitance
C
IN–OUT
— — 0.5 — — — pF