Electrical Characteristics
T
a
= 25°C T
a
= –40 to 85°C
Item Symbol V
CC
(V)
Min Typ Max Min Typ Max
Unit Test Conditions
3.0 to 3.6 — — — 1.5 — —
V
IH
4.5 to 5.5 — — — 2.0 — —
3.0 to 3.6 — — — — — 0.6
Input voltage
V
IL
4.5 to 5.5 — — — — — 0.8
V Control input only
3.3 — — — — 0.10 —
Hysteresis
voltage
V
H
5.0 — — — — 0.15 —
V V
T
+
– V
T
–
3.0 — 50 150 — — 190
On-state switch
resistance
R
ON
4.5 — 40 75 — — 100
Ω
V
IN
= V
CC
or GND
V
C
= V
IH
I
T
= 1 mA
3.0 — 100 180 — — 225
Peak on
resistance
R
ON (P)
4.5 — 50 100 — — 125
Ω
V
IN
= V
CC
to GND
V
C
= V
IH
I
T
= 1 mA
Off-state switch
leakage current
I
s (OFF)
5.5 — — ±0.1 — — ±1.0 µA
V
IN
= V
CC
, V
OUT
= GND
or V
IN
= GND,
V
O
= V
CC
, V
C
= V
IL
On-state switch
leakage current
I
s (ON)
5.5 — — ±0.1 — — ±1.0 µA
V
IN
= V
CC
or GND
V
C
= V
IH
Input current I
IN
0 to 5.5 — — ±0.1 — — ±1.0 µA V
IN
= 5.5 V or GND
I
CC
5.5 — — — — — 10 µA V
IN
= V
CC
or GND
Quiescent
supply current
∆I
CC
5.5 — — — — — 1.5 mA V
IN
= 3.4 V
Control input
capacitance
C
IC
— — 3.5 — — — — pF
Switch terminal
capacitance
C
IN / OUT
— — 4.0 — — — — pF
Feed through
capacitance
C
IN–OUT
— — 0.5 — — — — pF
Switching Characteristics
• V
CC
= 3.3 ± 0.3 V
Ta = 25°C Ta = –40 to 85°C
Item Symbol
Min Typ Max Min Max
Unit
Test
Conditions
FROM
(Input)
TO
(Output)
— 1.5 6.0 — 10.0 C
L
= 15 pF
Propagation
delay time
t
PLH
t
PHL
— 4.0 9.0 — 12.0
ns
C
L
= 50 pF
IN/OUT
or OUT/IN
OUT/IN
or IN/OUT
— 4.0 11.0 — 15.0 C
L
= 15 pF
Enable time
t
ZH
t
ZL
— 6.0 18.0 — 22.0
ns
C
L
= 50 pF
C
IN/OUT
or OUT/IN
— 5.0 11.0 — 15.0 C
L
= 15 pF
Disable time
t
HZ
t
LZ
— 8.0 18.0 — 22.0
ns
C
L
= 50 pF
C
IN/OUT
or OUT/IN
• V
CC
= 5.0 ± 0.5 V
Ta = 25°C Ta = –40 to 85°C
Item Symbol
Min Typ Max Min Max
Unit
Test
Conditions
FROM
(Input)
TO
(Output)
— 1.0 4.0 — 7.0 C
L
= 15 pF
Propagation
delay time
t
PLH
t
PHL
— 3.0 6.0 — 8.0
ns
C
L
= 50 pF
IN/OUT
or OUT/IN
OUT/IN
or IN/OUT
— 3.0 7.0 — 10.0 C
L
= 15 pF
Enable time
t
ZH
t
ZL
— 5.0 12.0 — 16.0
ns
C
L
= 50 pF
C
IN/OUT
or OUT/IN
— 4.0 7.0 — 10.0 C
L
= 15 pF
Disable time
t
HZ
t
LZ
— 6.0 12.0 — 16.0
ns
C
L
= 50 pF
C
IN/OUT
or OUT/IN