Renesas M30240T-RPD-E Switch User Manual


 
( 34 / 58 )
3.7 Modifying the MCU File for M3T-PD30
It is necessary to change the contents of the MCU file depending on the MCU being developed. For
the M30240 Group MCUs, make M30240.MCU in the same directory as emulator debugger M3T-
PD30.
The MCU file contains the following information: SFR area, internal RAM area, internal ROM area
and firmware file name. Set these according to the MCU being developed. Use your editor to edit the
MCU file.
0: SFR area starting address
3FF : ending address
400 : Internal RAM starting address
17FF : ending address
E0000 : Internal ROM starting address
FFFFF : ending address
M30620B : Firmware file name (Do not change.)
0: Expansion No. M3T-PD30 V.4.00 or greater required (Do not change.)