5. Connection Procedure (See Figure 3)
The procedure for connecting the M30260T-48FPD is shown
below.
(1) Mount the NQPACK048SD on the user system.
(2) Attach the YQPACK048SD on the NQPACK048SD.
(3) Secure the four corners of the YQPACK048SD with the
YQ-GUIDE's.
●
Do not use the screws included with the
YQPACK048SD for fixing the YQPACK048SD.
●
The screwdriver included with the NQPACK048SD is
used for fixing the HQPACK048SD. Do not use if for
fixing the YQ-GUIDE's.
(4) Attach the M30290T-EPB or M30290T2-CPE and the
M30290T-PTCB.
(5) Attach the M30260T-48FPD to the NQPACK048FPD.
Figure 3 Connection procedure of the M30260T-48FPD
6. External Dimensions and a Sample Foot Pattern (See Figure 4)
Figure 4 External dimensions and a sample foot pattern of the M30260T-48FPD
48-pin 0.5-mm-pitch
(48P6Q-A) foot pattern
YQ-GUIDE (x4) *
YQPACK048SD *
NQPACK048SD *
(1)
(2)
(4)
(5)
M30290T-PTCB
M30260T-48FPD
(3)
M30290T-EPB
or
M30290T2-CPE
Be sure to use a
Phillips screwdriver.
34.0
16.5 32.0
0.25
0.5
7.0
10.0
7.0
10.0
Unit: mm