5. Connection Procedure (See Figure 3)
The procedure for connecting the M3T-FLX-80NSD is shown
below.
(1) Mount the NQPACK080SD-ND on the target system.
(2) Attach the YQPACK080SD on the NQPACK080SD-ND.
(3) Secure the four corners of the YQPACK080SD with the
YQ-GUIDE's.
Do not use the screws included with the
YQPACK080SD for fixing the YQPACK080SD.
The screwdriver included with the
NQPACK080SD-ND is used for fixing the
HQPACK080SD. Do not use if for fixing the
YQ-GUIDE's.
(4) Attach the M3T-FLX-80NSD on the YQPACK080SD.
(5) Connect the probe tip of the emulator and the
M3T-FLX-80NSD.
Figure 3 Connection procedure of the M3T-FLX-80NSD
6. External Dimensions and a Sample Foot Pattern
Figure 4 External dimensions and a sample foot pattern of the M3T-FLX-80NSD
(5)
(4)
(1)
(2)
(3)
Use a slotted screwdriver.
YQ-GUIDE (x4)
YQPACK080SD
NQPACK080SD-ND
80-pin 0.5-mm-pitch
(80P6Q-A) foot pattern
FLX100 cable
M3T-FLX-80NSD
: No. 1 pin
Be sure to align the pins.
CN1
M
A
D
E
I
N
J
A
P
A
N
J1J2
M3T-FLX-80NSD
1
25 25 2626
50 501
27.0
27.0
12.019.5
-----------
-----------
----
----
0.25
0.5
15.1
11.1
15.1
11.1
31.5
REV. A