Troubleshooting
Cannot record digitally
The CD player’s digital connection is not accepted.
The
MASTER CLOCK
is set to “INT”.
The DIGITAL IN connector (optical/coaxial/R-BUS)
was not properly selected.
The sampling rate of the recording destination project is
different than the sampling rate of the digital audio
device.
Match the sample rate setting of the digital audio
device to the setting of the project. If it is not
possible to change the sample rate of the digital
audio device, create a new project with that sample
rate.
The digital signal is not being transmitted from the
digital audio device.
Some digital audio devices do not output a digital
signal unless they are in play mode. If this is the
case, put your digital audio device in standby
(pause) mode before putting the VS-2400CD into
record mode.
The digital signal format is different.
Some digital audio devices may use a special digital
signal format. Please connect to a digital audio
device that is compatible with S/P DIF.
Noise and distortion appear in the
recorded sound
Input sensitivity settings are incorrect.
If input sensitivity settings are too high, the
recorded sound will be distorted. Conversely, if they
are too low, the recorded sound will be obscured by
noise. Adjust the SENS knobs so that the level
meters move at as high a level as possible, within the
range of -12 dB to 0 dB.
The equalizer is being used with the input mixer.
Some equalizer settings may cause the sound to
distort even if the channel’s peak indicator does not
show cliping. Readjust the equalizer.
“ATT” (Attenuator) setting is incorrect.
If noise or distortion occurred as a result of track
bouncing, the track output levels were too high.
The play back pitch is strange
The Vari-Pitch function is turned on (the VARI PITCH
icon is appears in the display).
The time compression/expansion function is being used.
Disk drive problems
The internal hard disk is not being
recognized
The hard disk has not been installed correctly.
The “Partition” settings are not right.
We recommend setting the partition size to “10GB.”
Although the Region Erase operation is finished, the
available recording time is not increased.
The audio data is erased by Region Cut,
RegionErase or Phrase Delete etc., the data that is no
longer played back is not actually erased from the
hard disk. If you wish to increase the available
recording time, please read “If “Disk Full!” appears
in the display (Project Optimize)” .
Internal Effects
Effects cannot be used
The VS8F-2 has not been installed correctly.
Only one VS8F-2 has been installed (when EFFECT 3 and
4 cannot be used).
You are attempting to select the algorithm for Reverb,
Gated Reverb, Vocoder2 (19), Voice Transformer or
Mastering Tool Kit with FX2 or FX4.
You have already selected Vocoder 2 (19), Voice
Transformer or Mastering Tool Kit with FX1 or FX3 and
therefore cannot use FX2 or FX4.
I’d like to change the order of an effect algorithm.
The connection orders cannot be altered. They can
only be turned on or off. For more detailed
information on what goes on with the algorithm
orders, please refer to the “Algorithm List” (p. 45).
CD-RW Drive Problems
I made an audio CD on the CD-R/RW
drive, but it doesn’t play on a
consumer CD player.
The disc was not finalized. When making audio CDs, set
“FINALIZE” to “On” or “OnlyFin.”.
Audio CD’s created using a CD-RW disc cannot be
played on a conventional CD player. Please use a CD-R
disc.