Royal Sovereign RSC-1400C Laminator User Manual


 
1817
RSC -1400C/H
16. SPECIFICATIONS
Description RSC-1400H RSC-1400C
Power supply AC 100, 200, 220~240V 50/60Hz 120V 60Hz
Power consumption 1650W, 800W 100W
Max laminating width 1400mm / 55"
Film thickness 25~250 mic / 1~10mil
Max laminating speed 5m/min / 16.4ft/min
Ready time 10min Not applicable
Heating method Hot Roller None
Driving motor DC geared
Max Temperature contro
l50
/ 22 F
Not applicable
Speed control 9 settings
Transport type 2 Roller
Film core size Auto grip (2",3")
Cross cutter Yes
Hot lamination Yes No
Cold lamination Yes
Mounting thickness 15mm / 0.6"
Take up system Chain link to mai motor
Reverse Yes
Remote control Yes
Foot pedal Yes
Unit dimensions 1710
650 1210 (mm)
(w x d x h) 67.5" 21.5" 47.5"
Unit weight 164kg / 361lbs
Carton dimensions 1960
900 850(mm)
(w x d x h) 77" 35.5" 33.5"
Gross Weight 270kg / 595lbs
14. MAINTENANCE
15. TROUBLESHOOTING
Cleaning the Body of the laminaor
1. To clean the machine body, dampen a cloth with water only and gently wipe the machine clean.
Removing Adhesive Build Up
1. Remove the film from the laminator.
2. Use a damp (water only) cloth and a rubber gum eraser to remove the adhesive on the
Teflon (metal) and silicone rollers.
Lubrication
1. Drive chain and sprockets should be lubricated with either a light coat of gear lube or
heavy grease (lithium grease) after 6 months or 1000 hours of operation, whichever
comes first.
Note: Rub firmly but do not scrub the rollers vigorously as this may scratch the
surface.Do not use sharp metal objects, steel wool, or abrasives, as these
may also damage the rollers.
Problem Cause Solution
Machine will not turn
on:
a. Power plug is not plugged in.
b. Power switch is in “0” (Off) position.
c. Tripped circuit breaker.
d. Blown main power fuse.
a. Plug the power cord into appropriate
outlet.
b. Put the power switch to the “I” (On)
position.
c. Reset the circuit breaker.
d. Replace the fuse.
There is power, but the
rollers are not turning
after the “RUN” button
is pressed:
a. Emergency switch (es) is (are)
engaged.
b. Paper guide is not installed correctly.
c. Blown motor fuse.
a. Disengage the emergency switch (es).
b. Properly install the paper guide so that
the micro switch is activated.
c. Replace the motor fuse.
The unit is not heating
up:
a. Did not raise the temperature. a. Raise the temperature.
Curled lamination:
a. Upward curl.
b. Downward curl.
a. Loosen the top roll film tension.
b. Loosen the bottom roll film tension.