Royal Sovereign RSL-380 Laminator User Manual


 
2 The Wire-Temp Fuse is disconnected
1) Test if the Wire-Temp Fuse is disconnected with Multi-tester.
2) If disconnected, replace it with new one.
3. MAIN FUSE is disconnected.(except RSL-380)
1) Test if the Main Fuse is disconnected with Multi-tester.
2) If disconnected, replace it with new one.
1) Disconnect the heater wire from the Bi-metal.
2) Unfasten 2 screws holding the Bi-metal.
3) Replace it with new one.
4. The Bi-metal is defective.
5
WIRE-TEMP FUSE
MAIN
FUSE
BI-METAL