RuggedCom RS900W Switch User Manual


 
www.RuggedCom.com
6
RuggedWireless™ RS900W
RuggedWireless
TM
RS900W
Wireless Ethernet with Integrated 8-Port Managed Switch
EMI and Environmental Type Tests
Environmental Type Tests
Test Description Test Levels Severity Levels
IEC 60068-2-1 Cold Temperature Test Ad -40°C, 16 Hours N/A
IEC 60068-2-2 Dry Heat Test Bd +85°C, 16 Hours N/A
IEC 60068-2-30 Humidity (Damp Heat, Cyclic) Test Db
95% (non-condensing),
55°C , 6 cycles
N/A
IEC 60255-21-1 Vibration Tests Fc 2g @ (10 - 150) Hz Class 2
1
IEC 60255-21-2 Shock Tests Ea 30g @ 11mS Class 2
IEC 61000-6-2 EMC Generic Standard: Immunity for Industrial Environments
Test Description Levels RuggedCom Test Level Performance Criteria*
IEC 61000-4-2 ESD
Enclosure Contact +/- 4kV +/- 8kV B
Enclosure Air +/- 8kV +/- 15kV B
IEC 61000-4-3 Radiated RFI Enclosure ports 10 V/m, 80 to 1000Mhz 20V/m A
IEC 61000-4-4 Burst (Fast Transient)
Signal ports +/- 1kV @ 5kHz +/- 4kV @ 2.5kHz B
D.C Power ports +/- 2kV @ 5kHz +/- 4kV B
A.C. Power ports +/- 2kV @ 5kHz +/- 4kV B
IEC 61000-4-5 Surge
Signal ports +/- 1kV line-to-earth
+/- 2kV line-to-earth, +/- 2kV
line-to-line
B
D.C Power ports +/- 0.5kV line-to-earth/line
+/- 4kV line-to-earth, +/- 2kV
line-to-line
B
A.C. Power ports
+/- 2kV line-to-earth, +/- 1kV
line-to-line
+/- 4kV line-to-earth, +/- 2kV
line-to-line
B
IEC 61000-4-6 Induced (Conducted) RFI
Signal ports 10V @ 0, 5-80 MHz 10V @ 0, 5-80 MHz A
D.C Power ports 10V @ 0, 5-80 MHz 10V @ 0, 5-80 MHz A
A.C. Power ports 10V @ 0, 5-80 MHz 10V @ 0, 5-80 MHz A
Earth ground ports 10V @ 0, 5-80 MHz 10V @ 0, 5-80 MHz A
IEC 61000-4-8 Magnetic Field Enclosure ports 30 A/m @ 50, 60 Hz
40 A/m continuous, 1000
A/m for 1s
A
IEC 61000-4-11 Voltage Dips A.C. Power ports
30% reduction for 0.5
period
30% for 1 period B
>95% reduction for 250
periods
100% for 5 periods, 100%
for 50 periods
C
IEC 60255-5 Dielectric Strength
Signal ports
2kVac
(Fail-Safe Relay output)
2kVac
(Fail-Safe Relay output)
N/A
D.C. Power ports 2kVac 2kVac N/A
A.C. Power ports 2kVac 2kVac N/A
IEC 60255-5 H.V. Impulse
Signal ports
5kV
(Fail-Safe Relay output)
5kV
(Fail-Safe Relay output)
N/A
D.C. Power ports 5kV 5kV N/A
A.C. Power ports 5kV 5kV N/A
Notes: 1. Class 2 refers to "Measuring relays and protection equipment for which a very high security margin is required or where the vibration levels are very high, ( e.g. shipboard application and for severe transportation conditions")
NEMA TS-2 Requirements
Test Description Levels Performance Criteria*
TS-2 1998, Section 2, para 2.2.7.3
Temperature: Low Temperature/Low
Voltage
89.0 VAC @ -34°C
EUT Continued to function properly during
and following all temperature and humidity
testing
TS-2 1998, Section 2, para 2.2.7.4
Temperature: Low Temperature/High
Voltage
135.0VAC @ -34°C
TS-2 1998, Section 2, para 2.2.7.5
Temperature: High Temperature/High
Voltage
135.0VAC @ + 75°C
TS-2 1998, Section 2, para 2.2.7.6
Temperature: High Temperature/Low
Voltage
89.0VAC @ + 75°C
TS-2 1998, Section 2 para. 2.2.8.4 Vibration Endurance Test 0.5g @ 30Hz for 1hr on all three planes
EUT functioned properly following test pro-
cedure. No physical damage.
TS-2 1998, Section 2, para 2.1.10 Mechanical Shock
+/-10g half sine wave for 11msec on all
three planes
EUT functioned properly following test pro-
cedure. No physical damage.
TS-2 1992, Section 2, para. 2.1.6.1
Electrical Transients: High Repetition Noise
(AC Terminals)
One +/-300VDC pulse every other cycle
once every 3 seconds across 360 ° of line
cycle (2500W peak)
EUT functioned properly during and follow-
ing test procedure. No damage
TS-2 1998, Section 2 para. 2.1.6.2
Electrical Transients: Low-Repetition High
Energy (AC Terminals
One +/-600VDC pulse every second, ran-
domly distributed across 360 ° of line
cycle. Ten pulses total.
EUT functioned properly during and follow-
ing test procedure. No damage
TS-2 1998, Section 2, para 2.1.7 Electrical Transients: I/O Terminals
One +/-300VDC pulse every second, mini-
mum 5 pulses per port
EUT functioned properly during and follow-
ing test procedure. No damage
TS-2 1992, Section 2, para. 2.1.8
Electrical Transients: Nondestruct
Transient Immunity (AC Terminals)
One +/-1000VDC pulse every two seconds,
3 per each polarity.
EUT functioned properly following test pro-
cedure. No damage