Rev. 1.02
- 13 -
SRP-350plusA&C
1-5 Setting the Memory Switches
This printer has “Memory Switch” set which is software switches. Memory Switch set has
“MSW1”, “MSW2”, “MSW8”, “MSW9” “Customize value”, “Serial communication condition”.
“Memory Switch setting utility” can change the Memory Switch set to ON or OFF as shown
in the table below. (default : all OFF)
NOTE
The Memory Switch is available to be changed by three methods.
- Memory Switch setting utility.
- Control from ESC/POS command.
Settings of the Memory Switch are stored in the NV memory : therefore, even if the printer
is turned off, the settings are maintained.
MSW1
Switch Function ON OFF
1~8 Reserved -- Fixed to OFF
MSW2
Switch Function ON OFF
1 Font Selection Font B (9 x 24) Font A (12 x 24)
2 Auto Cutter Function Full Cutting Partial Cutting
3~8 Code Page Selection Refer to following Table