Sanyo LC 2CR5 Power Supply User Manual


 
Cell Type 2CR5
Specifications
Typical Characteristics
1400mAh
6V
10mA
1500mA
3500mA
-40
℃~
60
40g
L34mm
W17mm
H45mm
Dimensions
Nominal Capacity
*1
Nominal Voltage
Standard Discharge Current
Weight
Max. Discharge Current
Temperature Range
Continuous
*2
Pulse
*3
Nominal capacity is determined to an end voltage of 4.0V when the battery is
allowed to discharge at a standard current level at 23
o
C.
*1
Current value is determined to be the level at which 50% of the nominal
capacity is obtained with an end voltage of 4.0V at 23
o
C.
*2
Current value for obtaining 2.0V cell voltage when pulse is applied for
15seconds at 50% discharge depth at 23
o
C.
*3
Discharge Characteristics of 2CR5
Cell Voltage(V)
Number of Cycles
Cell Voltage(V)
Number of Cycles
Pulse Discharge Characteristics of 2CR5
Pulse Discharge Characteristics of 2CR5
Cell Voltage(V)
Duration(hour)
0
200
400
600
800
1000
1200
1400
1600
1800
2.0
3.0
4.0
5.0
6.0
7.0
Pulse: 1.2A*3s on/7s off
Initial
23
o
C
-20
o
C
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2.0
3.0
4.0
5.0
6.0
7.0
Pulse: 0.9A*3s on/27s off
Initial
23
o
C
-20
o
C
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
2.0
3.0
4.0
5.0
6.0
7.0
Load: 400ohm
Temp.: 23
o
C
Initial
W
L
H