Sanyo MTR-5000 Server User Manual


 
Dimensions MTR-L03
[Unit : mm (inch)]
Specifications
Main functions
Data Acquisition System
Distributed by:
©2009 SANYO Printed in Japan 2009.7 MA
SHR147
SANYO Electric Co., Ltd.
Biomedical Division
http://biomedical.sanyo.com/
Set Value Information
Set values of SANYO biomedical devices can
be changed through the network.
*The above function is only applicable to remote-
controllable devices.
Map Display
Conditions of biomedical devices can be
displayed on the map intelligibly. (A device
showing a warning is displayed in red.)
Graph Display
Condition change of a selected channel can be
displayed on a graph.
Channel List
The condition of each channel (measurement
item) is displayed together with the upper and
lower limit setting data.
• SANYO cannot guarantee operations of all PCs satisfying the
above recommendable specifications.
• If other software is installed in a PC in which this software
was installed, information may be deleted due to malfunction.
Caution: SANYO guarantees the product under certain
warranty conditions. SANYO in no way shall be responsible for
any loss of content or damage to content.
• Appearance and specifications are subject to change without
notice.
65 (2.6”)
74 (2.9”)
58 (2.3”)
28 (1.1”)
63 (2.5”)
• Device-related information such as
temperature, CO
2 and O2 concentration,
and operating condition can be
integratedly monitored with one LAN-
connected personal computer.
Items that can be monitored depend on the
connected devices.
• Operating records are stored in
sequence in the PC. It is unnecessary to
fill in paper records or to enter in a
record book. It is easy to convert the
data into a graph.
Please note that there is a case in which data must
be recorded on a paper.
• Devices can be set up remotely from a
distant point, which saves entering a
clean room.
When the operating setting can be changed through
the network, it is impossible to change the
operation setting on the panel of each device.
• Setting the upper/lower limits will cause
you to be informed of an abnormality by
e-mail if the data is out of the range, and
you will also be informed when the
system recovers from the abnormality.
In addition, the system can be set so
that the device conditions will be
informed at a designated time whether
or not there is an abnormality.
A mail account which can be connected to an
SMTP-compatible mail server is required.
• Two-step/day operation to set up two
different temperatures is
programmable.
For example, energy saving can be expected by
changing to different setting temperatures for day
and night operations.
• System access is protected by
ID/Password.
Features
SANYO Electric Co., Ltd., Biomedical Division, Gunma is certified for:
Quality management system: ISO9001 / Medical devices quality management system: ISO13485 / Environmental management system: ISO14001
Note:
All screen images shown in the catalog are composite images.
In the unlikely event of a mechanical failure, the contents of
the incubator and any recorded data cannot be guaranteed.
Model
Product name
Exterior
dimensions
(W x D x H)
Power supply
Output terminal
Compatible
protocol
Note
Model
Product name
No. of devices to
be monitored
Devices to be
monitored
Monitoring PC
Recommendable
specifications
MTR-L03
Ethernet (LAN) Interface
74 x 63 x 58mm
(2.9” x 2.5” x 2.3”)
DC5V (to be supplied from the
attachment device)
RJ-45 twist pair cable 8-pin
connector
TCP/IP *Only static IP
(Impossible to use DHCP.)
MTR-L03 is not equipped with
sensors for temperature, etc. As
information such as in-box
temperature, etc., results
measured at the sensors of the
incubators and freezers are
transmitted to the network.
MTR-5000
SANYO Data acquisition software
32 devices at most (up to 100 ch)
SANYO biomedical devices
connected to MTR-L03 or MTR-
480 (RS232C or RS-485)
CPU: Core2DUO or higher
Memory: 1GB or more
HDD: 80 GB or more
OS: Microsoft Windows XP SP3
(compatible with Windows Vista)