Schumacher PID-200 Power Supply User Manual


 
7
DIGITAL DISPLAY
LED Lights – indicate status of the Digital Display.
The Digital Display identies the current status of the PID-200.
INPUT VOLTAGE: Voltage of vehicle’s battery.
OUTPUT VOLTAGE: Voltage supplied to device through AC
receptacle.
POWER OUT: Power or wattage supplied to device plugged
into the inverter.
An audio alarm will sound when the following occurs:
To stop the alarm, press the switch to OFF.
Inverter is not functional. See warranty and call Customer
Service 800-621-5485 (Hours: 7 a.m. – 4:30 p.m. CST).
Vehicle’s battery voltage is more than 15.5 Volts.
The continuous load demand from the device exceeds
200 watts. Use a device drawing less than 200 continu-
ous watts.
Inverter is overheated and automatically turns off for
a period of 1–3 minutes to cool. Make sure inverter is
well ventilated.
Vehicle’s battery voltage is less than 10.5 Volts.
Short circuit, power surge or overload in the device.