Schumacher PID-760 Power Supply User Manual


 
8
5. Display shows HiP. Device demands more than
760 Watts continuous power.
Cycle inverter power OFF and ON.
If problem persists, use a larger inverter or a smaller
device.
6. Display shows HoT. Inverter is too hot.
Increase ventilation to inverter.
Move inverter to a cooler area.
Reduce the power consumption of the device.
Inverter will automatically reset after cooling.
PROBLEM: Inverter Does Not Turn On
Reason/Solution
1. Poor contact at terminals.
Unplug and reinsert PID-760.
2. Fuse is blown.
A blown fuse is usually caused by reverse polarity
or a short circuit within the inverter. To replace, con-
tact a qualied service technician who will diagnose
the inverter and replace the fuse(s) with the appro-
priate replacement(s).
3. Inverter may be defective.
See warranty and call Customer Service 800-621-
5485 (Hours: 7 a.m. – 4:30 p.m. CST).