Schumacher PSJ-4424 Power Supply User Manual


 
NOTE: A fully charged battery will read 100%
5. Recharge the jump starter after use and every 3 months to full
charge status to extend the battery’s life.
If the charger is plugged in for over 48 hours and the battery(s) do
not fully charge in this time, CHG ERR is shown on the Display. The
batteries may be getting old and will no longer accept a charge.
TO ORDER AND REPLACE JAWS
Part Number Description
QTY Per
Clamp
0099000680 TOP BATTERY CLAMP JAW 1
0099000705 BOTTOM BATTERY CLAMP JAW 1
3899001640 BRAIDED CABLE 1
5199000636 SCREW, JAW TO CLAMP 2
5199001010 SCREW, JAW TO CABLE 1
LIMITED WARRANTY
Schumacher Electric Corporation warrants your unit to be free from defects in material and workmanship, excepting abuse or misuse, for a
period of one year from the date of sale to the original user or consumer purchaser. If your unit fails or malfunctions within the rst 30 days
of the warranty, we will replace it with a new unit. If your unit malfunctions or fails within the 12 month warranty period because of a defect in
material or workmanship, we will repair without charge.
The internal battery, excluding units with swollen batteries or melted battery terminals, carries a 90-day warranty from the date of purchase.
Proof of purchase required. All battery replacements will be at the sole discretion of the manufacturer or his designated agents.
This warranty is in lieu of all other express warranties. The duration of any implied warranty, including but not limited to any implied warranty
of merchantability or tness for a particular purpose, made in respect to your unit is limited to the period of the express warranty set forth
above.
For warranty service, return your product, with proof of purchase, to the factory or a designated agent: Schumacher Electric Corporation
Warranty Service Department, 1025 E. Thompson Street, PO Box 280, Hoopeston, IL 60942. Phone 1-800-621-5485, Customer Service
hours: 7 AM to 4 PM CST.
You will be responsible for all insurance and freight or other transportation charges to the factory or point of repair. We will return your unit
freight prepaid if repair is covered under warranty. Your unit should be properly packed to avoid damage in transit, since we will not be
responsible for any such damage.
In no event shall Schumacher Electric Corporation be liable for consequential or incidental damages. Some states do not allow limitations on
the length of the implied warranty or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions
may not apply to you. This warranty gives you specic legal rights and you may also have other rights which vary from state to state.
Send Warranty Product Repairs to: Schumacher Electric Corporation
1025 East Thompson, Hoopeston, IL 60942-0280
Call Customer Service if you have questions: 1-800-621-5485
CONTAINS SEALED NON-SPILLABLE LEAD-ACID BATTERY. MUST
BE DISPOSED OF PROPERLY.
WARNING: Possible explosion hazard. Contact with battery acid may
cause severe burns and blindness. Keep out of reach of children.
Battery Clamp Jaw Replacement
1. Secure clamp in open position using a vise or equivalent clamping
device. IMPORTANT: Make sure the rotary switch on the front
panel is in the O (OFF) position and the jump starter is not
plugged into a 110V AC electrical wall outlet.
2. Unscrew fastener securing the cables to the rear of the top
jaw.
3. Unscrew fasteners (2) securing the Copper Jaws to the plastic
clamp. Remove the jaws and braided cable.
4. Reverse for assembly.
STORAGE
The jump starter can be stored in any position. When the rotary
switch is in the 12V position, (or, for Model PSJ-4424, 12V or 24V)
the clamps are live and will produce arcing or sparking if they come
in contact with each other. To prevent accidental arcing, always keep
the clamps in the compartments and the switch in the OFF position
when not using it to jump start a vehicle.
All batteries are affected by temperature. The ideal storage
temperature is at 70 degrees Fahrenheit. Performance varies based
on battery temperature conditions.
DSR Professional Products
Schumacher Electric Corporation
801 Business Center Drive, Mount Prospect, IL 60056-2179