Seagate 100743772 Personal Computer User Manual


 
Seagate Desktop HDD Product Manual, Rev. B 11
www.seagate.com Drive Specifications
2.11 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in Table 4.
2.12 Warranty
To determine the warranty for a specific drive, use a web browser to access the following web page:
http://www.seagate.com/support/warranty-and-replacements/
From this page, click on “Check to see if the drive is under Warranty”. Users will be asked to provide the drive serial
number, model number (or part number) and country of purchase. The system will display the warranty information
for the drive.
2.13 Agency certification
2.13.1 Safety certification
These products are certified to meet the requirements of UL60950-1, CSA60950-1 and EN60950 and so marked
as to the certify agency.
2.13.2 Electromagnetic compatibility
Hard drives that display the CE mark comply with the European Union (EU) requirements specified in the
Electromagnetic Compatibility Directive (2004/108/EC) as put into place 20 July 2007. Testing is performed to the
levels specified by the product standards for Information Technology Equipment (ITE). Emission levels are defined
by EN 55022, Class B and the immunity levels are defined by EN 55024.
Drives are tested in representative end-user systems. Although CE-marked Seagate drives comply with the
directives when used in the test systems, we cannot guarantee that all systems will comply with the directives. The
drive is designed for operation inside a properly designed enclosure, with properly shielded I/O cable (if necessary)
and terminators on all unused I/O ports. Computer manufacturers and system integrators should confirm EMC
compliance and provide CE marking for their products.
Table 4 Radio frequency environments
Test Description
Performance
level
Reference
standard
Electrostatic discharge Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV B EN61000-4-2: 95
Radiated RF immunity 80MHz to 1,000MHz, 3 V/m,
80% AM with 1kHz sine
900MHz, 3 V/m, 50% pulse modulation @
200Hz
A EN61000-4-3: 96
ENV50204: 95
Electrical fast transient ± 1 kV on AC mains, ± 0.5 kV on external I/O B EN61000-4-4: 95
Surge immunity ± 1 kV differential, ± 2 kV common,
AC mains
B EN61000-4-5: 95
Conducted RF immunity 150kHz to 80MHz, 3 Vrms, 80% AM with 1kHz
sine
A EN61000-4-6: 97
Voltage dips, interrupts 0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN61000-4-11: 94