Seagate 7200.8 PATA Computer Drive User Manual


 
Barracuda 7200.8 PATA Product Manual, Rev. F
17
2.10 Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined
by the following equation:
(Number of seeks per second = 0.4 / (average latency + average access time)
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels.
2.11 Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 6: Radio frequency environments
Table 5: Fluid Dynamic Bearing (FDB) motor acoustics
Acoustic mode
Idle* Performance seek
2.8 bels (typ)
3.4 bels (max)
3.7 bels (typ)
3.9 bels (max)
Test Description
Performance
level
Reference
standard
Electrostatic discharge Contact, HCP, VCP: ± 4
kV; Air:
± 8 kV
B EN 61000-4-2: 95
Radiated RF immunity 80 to 1,000 MHz, 3 V/m,
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse
modulation @ 200 Hz
A EN 61000-4-3: 96
ENV 50204: 95
Electrical fast transient ± 1 kV on AC mains, ± 0.5 kV on
external I/O
B EN 61000-4-4: 95
Surge immunity ± 1 kV differential, ± 2 kV com-
mon, AC mains
B EN 61000-4-5: 95
Conducted RF immunity 150 kHz to 80 MHz, 3 Vrms,
80% AM with 1 kHz sine
A EN 61000-4-6: 97
Voltage dips, interrupts 0% open, 5 seconds
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
C
C
C
B
EN 61000-4-11: 94