Seagate ST1000LM014 Computer Drive User Manual


 
Momentus XT Product Manual, Rev. B 13
2.10.6 Shock
All shock specifications assume that the drive is mounted securely with the input shock applied at the drive
mounting screws. Shock may be applied in the X, Y or Z axis.
2.10.6.1 Operating shock
These drives comply with the performance levels specified in this document when subjected to a maximum
operating shock of 350 Gs based on half-sine shock pulses of 2 ms. Shocks should not be repeated more than
one time per axis.
2.10.6.2 Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation
in performance when subsequently put into operation is 800 Gs based on a nonrepetitive half-sine shock pulse
of 2 ms duration.
The nonoperating shock level that the drive can experience without incurring physical damage or degradation
in performance when subsequently put into operation is 900 Gs based on a nonrepetitive half-sine shock pulse
of 1 ms duration.
The nonoperating shock level that the drive can experience without incurring physical damage or degradation
in performance when subsequently put into operation is 600 Gs based on a nonrepetitive half-sine shock pulse
of 0.5 ms duration.
2.10.7 Vibration
All vibration specifications assume that the drive is mounted securely with the input vibration applied at the
drive mounting screws. Vibration may be applied in the X, Y or Z axis.
2.10.7.1 Operating vibration
The maximum vibration levels that the drive may experience while meeting the performance standards speci-
fied in this document are specified below.
2.10.7.2 Nonoperating vibration
The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or degrada-
tion in performance when subsequently put into operation are specified below
.
2.11 Acoustics
Drive emission of sound is measured consistent with the ECMA-74 and its referenced standards. Testing is
conducted at room temperature (approximately 25
°C). Emission levels are reported as the total A-weighted
sound power levers for steady state, idle, and active seeks modes of operation.
5–500 Hz 1.0 Gs (0 to peak). Max displacement may apply below 10 Hz.
5–500 Hz: 5 Gs (0 to peak). Max displacement may apply below 22 Hz.
Table 5: Drive A-weighted Sound Power Levels (SWL, BA)
Idle* Performance seek
2.3 bels (typ)
2.5 bels (max)
2.5 bels (typ)
2.7 bels (max)