Seagate ST1000NM0063 Computer Drive User Manual


 
58 Constellation ES Series SAS Product Manual, Rev. F
12.3.1 Inquiry data
Table 9 lists the Inquiry command data that the drive should return to the initiator per the format given in the
SAS Interface Manual.
Table 9: Constellation ES inquiry data
Bytes Data (hex)
0-15 00 00 xx** 12 8B 00 30 02 53 45 41 47 41 54 45 20 Vendor ID
16-31 [53 54 33 32 30 30 30 34 34 34 53 53} 20 20 20 20
Product ID
32-47 R# R# R# R# S# S# S# S# S# S# S# S# 00 00 00 00
48-63 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
64-79 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
80-95 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
96-111 00 43 6F 70 79 72 69 67 68 74 20 28 63 29 20 32* *Copyright
112-127 30* 30* 39* 20 53 65 61 67 61 74 65 20 41 6C 6C 20
notice
128-143 72 69 67 68 74 73 20 72 65 73 65 72 76 65 64 20
* Copyright year (changes with actual year).
** SCSI Revision support. See the appropriate SPC release documentation for definitions.
PP 10 = Inquiry data for an Inquiry command received on Port A.
30 = Inquiry data for an Inquiry command received on Port B.
R# Four ASCII digits representing the last four digits of the product firmware release number.
S# Eight ASCII digits representing the eight
digits of the product serial number.
[ ] Bytes 16 through 26 reflect model of drive. The table above shows the hex values for Model ST3200
0444SS.
Refer to the values below for the values of bytes 16 through 26 of your particular model:
ST32000444SS 53 54 33 32 30 30 30 34 34 34 53 53
ST32000445SS 53 54 33 32 30 30 30 34 34 35 53 53
ST32000446SS 53 54 33 32 30 30 30 34 34 36 53 53
ST31000424SS 53 54 33 31 30 30 30 34 32 34 53 53
ST31000425SS 53 54 33 31 30 30 30 34 32 35 53 53
ST31000426SS 53 54 33 31 30 30 30 34 32 36 53 53
ST3500414SS 53 54 33 35 30 30 34 31 34 53 53
ST3500415SS 53 54 33 35 30 30 34 31 35 53 53
ST3500416SS 53 54 33 35 30 30 34 31 35 53 53
12.3.2 Mode Sense data
The Mode Sense command provides a way for the drive to report its operating parameters to the initiator. The
drive maintains four sets of mode parameters:
1. Default values
Default values are hard-coded in the drive firmware stor
ed in flash E-PROM (nonvolatile memory) on the
drive’s PCB. These default values can be changed only by downloading a complete set of new firmware
into the flash E-PROM. An initiator can request and receive from the drive a list of default values and use
those in a Mode Select command to set up new current and saved values, where the values are change-
able.
2. Saved values